1,935 research outputs found

    Hammersmith Infant Neurological Examination in infants born at term : Predicting outcomes other than cerebral palsy

    Get PDF
    Aim We explored the ability of the Hammersmith Infant Neurological Examination (HINE) to identify cognitive performance delay at 2 years in a large cohort of infants born at term. Method We conducted a retrospective study of infants born at term at risk of neurodevelopmental impairments assessed using the HINE between 3 and 12 months post-term age and compared them with a cohort of typically developing infants born at term. All infants performed a neurodevelopmental assessment at 2 years of age using the Mental Development Index (MDI) of the Bayley Scales of Infant Development, Second Edition; the presence of cerebral palsy (CP) was also reported. The infants were classified as being cognitively normal/mildly delayed or significantly delayed (MDI < 70). The predictive validity of HINE scores for significantly delayed cognitive performance, in infants with and without CP, was calculated using specific cut-off scores according to age at assessment. Results A total of 446 at-risk and 235 typically developing infants (345 males, 336 females; mean [SD] gestational age 38.7 weeks [1.4], range 25-36 weeks) were included. Of the at-risk infants, 408 did not have CP at 2 years; 243 had a normal/mild delayed MDI and 165 had an MDI less than 70. Of the at-risk infants, 38 developed CP. HINE scores showed a good sensitivity and specificity, mainly after 3 months, for identifying significantly delayed cognitive performance in infants without CP. In those with CP, the score was associated with their cognitive performance. The comparison group had the highest HINE scores. Interpretation The HINE provides evidence about the risk of delayed cognitive performance at age 2 years in infants born at term with and without CP.Peer reviewe

    The Effectiveness of Osseodensification Drilling Protocol for Implant Site Osteotomy: A Systematic Review of the Literature and Meta-Analysis

    Get PDF
    Many different osteotomy procedures has been proposed in the literature for dental implant site preparation. The osseodensification is a drilling technique that has been proposed to improve the local bone quality and implant stability in poor density alveolar ridges. This technique determines an expansion of the implant site by increasing the density of the adjacent bone. The aim of the present investigation was to evaluate the effectiveness of the osseodensification technique for implant site preparation through a literature review and meta-analysis. The database electronic research was performed on PubMed (Medline) database for the screening of the scientific papers. A total of 16 articles have been identified suitable for the review and qualitative analysis—11 clinical studies (eight on animals, three on human subjects), four literature reviews, and one case report. The meta-analysis was performed to compare the bone-to-implant contact % (BIC), bone area fraction occupied % (BAFO), and insertion torque of clockwise and counter-clockwise osseodensification procedure in animal studies. The included articles reported a significant increase in the insertion torque of the implants positioned through the osseodensification protocol compared to the conventional drilling technique. Advantages of this new technique are important above all when the patient has a strong missing and/or low quantity of bone tissue. The data collected until the drafting of this paper detect an improvement when the osseodensification has been adopted if compared to the conventional technique. A significant difference in BIC and insertion torque between the clockwise and counter-clockwise osseodensification procedure was reported, with no difference in BAFO measurements between the two approaches. The effectiveness of the present study demonstrated that the osseodensification drilling protocol is a useful technique to obtain increased implant insertion torque and bone to implant contact (BIC) in vivo. Further randomized clinical studies are required to confirm these pieces of evidence in human studies

    Fiberless, Multi-Channel fNIRS-EEG System Based on Silicon Photomultipliers: Towards Sensitive and Ecological Mapping of Brain Activity and Neurovascular Coupling

    Get PDF
    Portable neuroimaging technologies can be employed for long-term monitoring of neurophysiological and neuropathological states. Functional Near-Infrared Spectroscopy (fNIRS) and Electroencephalography (EEG) are highly suited for such a purpose. Their multimodal integration allows the evaluation of hemodynamic and electrical brain activity together with neurovascular coupling. An innovative fNIRS-EEG system is here presented. The system integrated a novel continuous-wave fNIRS component and a modified commercial EEG device. fNIRS probing relied on fiberless technology based on light emitting diodes and silicon photomultipliers (SiPMs). SiPMs are sensitive semiconductor detectors, whose large detection area maximizes photon harvesting from the scalp and overcomes limitations of fiberless technology. To optimize the signal-to-noise ratio and avoid fNIRS-EEG interference, a digital lock-in was implemented for fNIRS signal acquisition. A benchtop characterization of the fNIRS component showed its high performances with a noise equivalent power below 1 pW. Moreover, the fNIRS-EEG device was tested in vivo during tasks stimulating visual, motor and pre-frontal cortices. Finally, the capabilities to perform ecological recordings were assessed in clinical settings on one Alzheimer’s Disease patient during long-lasting cognitive tests. The system can pave the way to portable technologies for accurate evaluation of multimodal brain activity, allowing their extensive employment in ecological environments and clinical practice

    Rapporto tecnico e delle attivitĂ  Campagna Oceanografica SAFE 2022

    Get PDF
    Le attività scientifiche realizzate nell’ambito della Campagna Oceanografica SAFE 2022 si inseriscono all’interno dell’Obiettivo Realizzativo 1 (OR1) del progetto PON_03 ‘Marine Hazard’ suddiviso in quattro Work Packages (WPs) articolati nel seguente modo: WP1 Studio dei potenziali giacimenti da sistemi idrotermali (GSI) sottomarini presenti nel Mar Tirreno sud-orientale e nello Stretto di Sicilia; WP2 Progetto Pilota di caratterizzazione geochimica ed ecologica dei GSI sul Palinuro Seamount; WP3 Sistema Acustico per la Rivelazione di Fenomeni di Idrotermalismo Sottomarino; WP4 Analisi di possibili impatti nell’ambiente marino e sottomarino. I dati ottenuti dalla Campagna Oceanografica SAFE 2022 contribuiranno ad arricchire le conoscenze sulla caratterizzazione chimico-fisica, biologica e microbiologica dei depositi e dei sistemi idrotermali. Le attività di ricerca si prospettano di fornire un quadro di conoscenze dettagliato e completo di ambienti che rappresentano oltre che possibili geositi e habitat prioritari anche un laboratorio per la ricerca e la scoperta di nuove biomolecole di interesse biotecnologico e l’individuazione di bioindicatori di attività geotermali e di marine hazard

    Incidence of adverse events at 3 months versus at 12 months after dual antiplatelet therapy cessation in patients treated with thin stents with unprotected left main or coronary bifurcations

    Get PDF
    Incidence and predictors of adverse events after dual antiplatelet therapy (DAPT) cessation in patients treated with thin stents (<100 microns) in unprotected left main (ULM) or coronary bifurcation remain undefined. All consecutive patients presenting with a critical lesion of an ULM or involving a main coronary bifurcation who were treated with very thin strut stents were included. MACE (a composite end point of cardiovascular death, myocardial infarction [MI], target lesion revascularization [TLR], and stent thrombosis [ST]) was the primary endpoint, whereas target vessel revascularization (TVR) was the secondary endpoint, with particular attention to type and occurrence of ST and occurrence of ST, CV death, and MI during DAPT or after DAPT discontinuation. All analyses were performed according to length of DAPT dividing the patients in 3 groups: Short DAPT (3-months), intermediate DAPT (3 to 12 months), and long DAPT (12-months). A total of 117 patients were discharged with an indication for DAPT ≀3 months (median 1: 1 to 2.5), 200 for DAPT between 3 and 12 months (median 8: 7 to 10), and 1,958 with 12 months DAPT. After 12.8 months (8 to 20), MACE was significantly higher in the 3-month group compared with 3 to 12 and 12-month groups (9.4% vs 4.0% vs 7.2%, p ≀0.001), mainly driven by MI (4.4% vs 1.5% vs 3%, p ≀0.001) and overall ST (4.3% vs 1.5% vs 1.8%, p ≀0.001). Independent predictors of MACE were low GFR and a 2 stent strategy. Independent predictors of ST were DAPT duration <3 months and the use of a 2-stent strategy. In conclusion, even stents with very thin strut when implanted in real-life ULM or coronary bifurcation patients discharged with short DAPT have a relevant risk of ST, which remains high although not significant after DAPT cessation

    Impact of structural features of very thin stents implanted in unprotected left main or coronary bifurcations on clinical outcomes

    Get PDF
    Objectives: To evaluate the independent clinical impact of stent structural features in a large cohort of patients undergoing unprotected left main (ULM) or coronary bifurcation percutaneous coronary intervention (PCI) with a range of very thin strut stents. Background: Clinical impact of structural features of contemporary stents remains to be defined. Methods: All consecutive patients enrolled in the veRy thin stents for patients with left mAIn or bifurcatioN in real life (RAIN) registry were included. The following stent structural features were studied: antiproliferative drugs (everolimus vs. sirolimus vs. zotarolimus), strut material (platinum-chromium vs. cobalt-chromium), polymer (bioresorbable vs. durable), number of crowns (<8 vs. ≄8) and number of connectors (<3 vs. ≄3). For small diameter stents (≀2.5 mm), struct thickness (74 vs. 80/81 ÎŒm) was also tested. Target lesion failure (TLF), a composite of target lesion revascularization and stent thrombosis, was the primary endpoint. Multivariate analysis was performed with Cox regression models. Results: Out of 2,707 patients, 110 (4.1%) experienced a TLF event after 16 months (12–18). After adjustment for confounders, an increased number of connectors (adjusted hazard ratio [adj-HR] 0.62, 95% confidence interval (CI) 0.39–0.99, p =.04) reduced risk of TLF, driven by stents with ≄2.5 mm diameter (HR 0.54, 95% CI 0.32–0.93, p =.02). This independent relationship was lost for stents with diameter <2.5 mm, where only strut thickness appeared to impact. Conversely, no independent relationship of polymer type, number of crowns, and the specific limus-family eluted drug with outcomes was observed. Conclusions: Among a range of contemporary very thin stent models, an increased number of connectors improved device-related outcomes in this investigated high-risk procedural setting

    Daily risk of adverse outcomes in patients undergoing complex lesions revascularization: a subgroup analysis from the RAIN-CARDIOGROUP VII study (veRy thin stents for patients with left mAIn or bifurcatioN in real life)

    Get PDF
    Introduction: Percutaneous coronary intervention (PCI) for complex lesions, including unprotected left main (ULM) and bifurcations, is gaining a relevant role in treating coronary artery disease with good outcomes, also thanks to new generation stents. The daily risk of adverse cardiovascular events and their temporal distribution after these procedures is not known.Methods: All consecutive patients presenting with a critical lesion of ULM or bifurcation treated with very thin struts stents, enrolled in the RAIN-Cardiogroup VII study, were analyzed. The daily risk of major acute cardiovascular events (MACE), target lesion revascularization (TLR) and stent thrombosis (ST) and their temporal distribution in the first year of follow-up was the primary endpoint. Differences among subgroups (ULM, patient presentation, kind of stent polymer) were the secondary endpoint.Results: 2745 patients were included, mean age 68 ± 11 years, 33.3% diabetics, 54.5% had an acute coronary syndrome (ACS); 88.5% of treated lesions were bifurcations, 27.2% ULM. Average daily risk was 0.022% for MACE, 0.005% for TLR and 0.004% for ST, in the first year. Bimodal distribution of adverse events, especially TLR, with an early peak in the first 50 days and a late one after 150 days, was observed. Patients with ULM presented a significantly higher daily risk of events, and ACS patients presented higher MACE risk. No difference emerged according to the type of stent polymer.Conclusions: The daily risk of adverse events in the first year after complex PCI in our study is acceptably low. PCI on ULM carries a higher risk of complications

    Anxiety and depression in keratotic oral lichen planus: a multicentric study from the SIPMO

    Get PDF
    Objectives: Oral lichen planus with exclusive keratotic reticular, papular, and/or plaque-like lesions (K-OLP) is a clinical pattern of OLP that may be associated with a complex symptomatology and psychological alteration. The aim of the study was to evaluate the prevalence of anxiety (A) and depression (D) in patients with K-OLP, analyzing the potential predictors which can affect mental health status. Methods: Three hundred K-OLP patients versus 300 healthy controls (HC) were recruited in 15 Italian universities. The Numeric Rating Scale (NRS), Total Pain Rating Index (T-PRI), and Hamilton Rating Scales for Depression and for Anxiety (HAM-D and HAM-A) were administered. Results: The K-OLP patients showed statistically higher scores in the NRS, T-PRI, HAM-D, and HAM-A compared with the HC (p-value < 0.001**). A and D were found in 158 (52.7%) and 148 (49.3%) K-OLP patients. Strong linear correlations were identified between HAM-A, HAM-D, NRS, T-PRI, and employment status and between HAM-D, HAM-A, NRS, T-PRI, employment status, and female gender. Multivariate logistic regression revealed that HAM-D and HAM-A showed the greatest increase in the R2 value for A and D in the K-OLP patients, respectively (DR2 = 55.5% p-value < 0.001**; DR2 = 56.5% p-value < 0.001**). Conclusions: The prevalence of A and D is higher in the K-OLP patients compared with the HC, also found in K-OLP subjects without pain, suggesting that the processing of pain may be in a certain way independent of the processing of mood. Clinical relevance: Mood disorders and pain assessment should be carefully performed in relation to K-OLP to obtain a complete analysis of the patients

    Transport Infrastructure Surveillance and Monitoring by Electromagnetic Sensing: The ISTIMES Project

    Get PDF
    The ISTIMES project, funded by the European Commission in the frame of a joint Call “ICT and Security” of the Seventh Framework Programme, is presented and preliminary research results are discussed. The main objective of the ISTIMES project is to design, assess and promote an Information and Communication Technologies (ICT)-based system, exploiting distributed and local sensors, for non-destructive electromagnetic monitoring of critical transport infrastructures. The integration of electromagnetic technologies with new ICT information and telecommunications systems enables remotely controlled monitoring and surveillance and real time data imaging of the critical transport infrastructures. The project exploits different non-invasive imaging technologies based on electromagnetic sensing (optic fiber sensors, Synthetic Aperture Radar satellite platform based, hyperspectral spectroscopy, Infrared thermography, Ground Penetrating Radar-, low-frequency geophysical techniques, Ground based systems for displacement monitoring). In this paper, we show the preliminary results arising from the GPR and infrared thermographic measurements carried out on the Musmeci bridge in Potenza, located in a highly seismic area of the Apennine chain (Southern Italy) and representing one of the test beds of the project
    • 

    corecore